Digital power meter high accuracy 0.5 three phase four wire LED multi-functional power analyzer RS485 communication protocol interface discrete input discrete output analog output CE certificate

Item No.: OH194E-9S4/2S4/3S4/AS4/DS4
OH194E-9S4: 96×96mm
OH194E-2S4: 120×120mm
OH194E-3S4: 80×80mm
OH194E-AS4: 72×72mm
OH194E-DS4: 48×48mm
  • LED multi-function power meter user manualDownload
  • Brochure LED Multi-function digital meter 1Download
INQUIRY
Description
I.The brief introduction of digital power meter high accuracy 0.5 three phase four wire LED multi-functional power analyzer RS485 communication protocol interface discrete input discrete output analog output CE certificate
The multi-function power meter is an ideal device for power quality monitoring. The meter has the function of simultaneously measuring current, voltage, frequency, active power, reactive power, apparent power, electric energy, power factor, etc. in the power grid. It is suitable for distributed detection of transformers, generator sets, capacitor banks and motors, and on-site monitoring of power grids and automation control systems. High accuracy 0.5 three phase four wire LED multi-functional power analyzer RS485 communication protocol interface discrete input discrete output analog output CE certificate
Multi-function power meters can also be used in factory automation and building automation. It can measure all the power parameters, and can be easily applied to the measurement and data recording of AC-opening and industrial power supply distributed measurement and control systems of various ranges. On the basis of our company's multi-function power meter, a simple monitoring system can be established by simply adding a central communication master display software based on IPC industrial computer.
Multi-function power monitor can replace many traditional panel or digital measuring instruments (such as ammeter, voltmeter, power meter, power factor meter, frequency meter, etc.), which can greatly reduce system cost, facilitate field wiring and improve system reliability. . The multi-function power monitor is equipped with a serial port (RS-485), which allows connection to an open-structure computer network; the Modbus-RTU communication protocol is used to facilitate computer programming or reading.
II.The main technical parameter, digital power meter high accuracy 0.5 three phase four wire LED multi-functional power analyzer RS485 communication protocol interface discrete input discrete output analog output CE certificate
Performance Parameter
Input measurement display Network Three-phase three-wire, three-phase four-wire
Voltage Rated value AC100V/220V/380V/500V
Overload Continuous: 1.2 times
Instantaneous: 2 times / 1S
Power consumption <1VA(Per phase)
Impedance >500KΩ
Accuracy Class 0.5
Current Rated value AC1A/AC5A
Overload Continuous:1.2 times
Instantaneous:10 times/5S 
Power consumption <0.4VA(Per phase)
Impedance <2mΩ
Accuracy Class 0.5
Frequency 40-60Hz  Accuracy:0.1Hz
Power Active, reactive, accuracy:1.0
Electric energy Active power accuracy class:1.0 Reactive power accuracy class:1.0
Display  Programmable switching (LED) display
Power supply Power supply range AC220V or A/DC80V~260V
Power consumption ≤2VA
Output Digital interface RS-485、MODBUS-RTU protocol
Pulse output 2 way energy pulse output
Environment Working environment -30~50℃  RH20%~90%(No condensation)
Storage environment -45~75℃  RH20%~90%
Security Power frequency withstand voltage 2KV/1min  AC Valid value
Insulation resistance ≥100MΩ
III.Functional module, digital power meter high accuracy 0.5 three phase four wire LED multi-functional power analyzer RS485 communication protocol interface discrete input discrete output analog output CE certificate
*Communication interface: standard 1 channel RS-485 communication, Modbus-RTU protocol Baud rate: 9600bps
*Switching output: support 4 relay outputs, capacity: AC250V/5A, DC30V/5A
*Digital input: support 4 dry node inputs
*Transmission output: support 4 way ANA outputs, 4-20mA/0-20mA or 0-5/0-10V
*Power pulse output: 1 active energy, 1 reactive energy pulse output, constant: 3200imp
IV.Apperance and dimension, digital power meter high accuracy 0.5 three phase four wire LED multi-functional power analyzer RS485 communication protocol interface discrete input discrete output analog output CE certificate

V.Meter's signal wiring
Relevant
Panel mount LED multifunction digital meter with voltage, current, active power, reactive power, power factor digital output function
OH194E-9S4B: 96×96mm
OH194E-2S4B: 120×120mm
OH194E-3S4B: 80×80mm
OH194E-AS4B: 72×72mm
OH194E-DS4B: 48×48mm
Southeast Asia hot sale precision 0.5 3-P 3-W LED multi-function low voltage switchgear use digital panel meter with RS485
OHD194E-9S4R: 96×96mm
OHD194E-2S4R: 120×120mm
OHD194E-3S4R: 80×80mm
OHD194E-AS4R: 72×72mm
Digital panel meter export precision 0.5 3-P 3-W LED multi-function measuring analyzer RS485 MODBUS-RTU DI DO AO with CE certificate
OHD194E-9S4RB:96×96mm
OHD194E-2S4RB:120×120mm
OHD194E-3S4RB:80×80mm
OHD194E-AS4RB:72×72mm
Review